Following are the prerequisites for installing
the March 2009 version of SFM software:
Starting with HP-UX 11i v3 March 2009 release, OnlineDiag
and SysFaultMgmt will be available through HP-UX Diagnostics Products
Collection (DiagProdCollection) Mega bundle. This Mega bundle will
be available only on web. Customer will require to install SysFaultMgmt,
OnlineDiag and ProviderSvcsBase product together from the DiagProdCollection
bundle because of the product dependency.
HP-UX 11i v3 February
2007 release
OpenSSL
Version A.00.09.07e.013 or later
EVM-EventMgr B.11.31
SysMgmtBase B.00.02.03 (Interface)
WBEM Services Version
A.02.07 or later
SysMgmtWeb
Version A.2.2.4 (HP-UX Web-Based System Management User Interface)
HP Systems Insight Manager
(HP SIM) version 5.0.01
ProviderSvcsBase (any version)
PropPlus A.01.00 or later (SysMgmtPlus)
NOTE: The ProviderSvcsBase product offers interface for user space
processes (typically, but not limited to, WBEM Indication Providers)
to retrieve error logs from HP-UX Kernel. Using these error logs WBEM
Indication Providers generate WBEM indications, when an event of interest
occurs on the system.
PropPlus or SysMgmtPlus is an enhancement plus package to HP-UX
System Management Homepage. SysMgmtPlus enhances the property pages
of SMH by adding additional details and introducing dynamic capability
to the web page.
SysMgmtWeb is optional. However, you will not be able to access
EVWEB GUI if SysMgmtWeb is not installed on the system.
All the prerequisites are available on the OE
media. You can select the SFM dependencies from the OE media while
installing the SFM software as a standalone component.
HP SIM is required only for remote administration
of indications and instances. HP SIM version 5.0.01 is the minimum
requirement. However, HP recommends you install HP SIM version C.05.02.01.xx.yy.
The mentioned versions of the software are minimum requirements.
All future versions support SFM by default.