Jump to content United States-English
HP.com Home Products and Services Support and Drivers Solutions How to Buy
» Contact HP
More options
HP.com home
Online Diagnostics Administrator's Guide: HP-UX 11i v1, HP-UX 11i v2, HP-UX 11i v3 > Chapter 2 Installing the Online Diagnostics Software

Software and Hardware Requirements

» 

Technical documentation

Complete book in PDF
» Feedback
Content starts here

 » Table of Contents

 » Glossary

 » Index

This section discusses software prerequisites for installing the Online Diagnostics software. It also lists the supported hardware and any special requirements they have.

Following are the prerequisites for installing the Online Diagnostics software:

  • PHKL_32653 (diag2) kernel patch

    NOTE: This patch is required for HP-UX 11i v2 systems only.
  • HP Serviceguard version A.11.04 or later for package failover

Both requirements are available on the Operating Environment (OE) media.

Table 2-1 lists the supported disk array devices and their requirements.

Table 2-1 Disk Arrays

ProductModel/Product NumberSpecial Requirements

HP AutoRAID Disk Array Supported by AutoRAID Disk Array Monitor (armmon)

12H
12

HP-UX 11i v1 (PHCO_23263) ARMServer version

HP High-Availability Disk Array: Supported by High-Availability Disk Array Monitor (ha_disk_array)

30/FC
20
10
None

HP Fast/Wide SCSI Disk Array: Supported by Fast Wide SCSI Disk Array Monitor (fw_disk_array)

C243XHANone

HP Fibre Channel High-Availability Disk Array: Supported by Disk Array FC60 Monitor (fc60mon)

HP SureStore E Disk Array
FC60

HP-UX 11i v1 (PHCO_26824)

HP StorageWorks Modular SAN Array 1000

HP StorageWorks Modular SAN Array 30

Supported by HP StorageWorks Modular SAN Array 1000 Monitor (msamon)

HP StorageWorks Modular SAN Array 1000

HP StorageWorks Modular SAN Array 30

Starting with the HP-UX 11i v1 June 2004 release and the HP-UX 11i v2 September 2004 release, MSA 1000 is supported on the following cards:

  • A9782A (2 GB/s, 64-bit PCI Dual Channel)

  • A9784A (2 GB/s, 64-bit PCI Dual Channel)

Starting with the HP-UX 11i v2 March 2004 release, Modular SAN Array 30 is supported on the following cards:

  • A6795A (2 GB/s, 64-bit 66 Mhz PCI)

  • A6826A (2 GB/s, 64-bit PCI Dual Channel)

HP StorageWorks Modular SAN Array 60

HP StorageWorks Modular SAN Array 70

Supported by HP StorageWorks Modular SAN Array 60/70 SAS Enclosure Monitor (msamon_sas)

HP StorageWorks Modular SAN Array 60

HP StorageWorks Modular SAN Array 70

Starting with the HP-UX 11i v2 March 2008 release and the HP-UX 11i v3 March 2008 release of OnlineDiag, msamon_sas monitors HP StorageWorks Modular SAN Array 60 and HP StorageWorks Modular SAN Array 70 on HP SC44Ge Host Bus Adapter (SAS HBA).

NOTE: The msamon_sas monitor is supported only on HP Integrity ®systems.

 

The Disk Monitor (disk_em) supports all disks bound to the sdisk and disc30 drivers, and not controlled by another event monitor, such as a disk array monitor. Hitachi XP128, XP256, XP512, XP1024 drives, and EMC Symetrix drives are not supported. These devices are monitored by other monitors.

Table 2-2 lists the supported High-Availability storage systems.

Table 2-2 High-Availability Storage Systems

ProductModel/Product NumberSpecial Requirements

HP High-Availability Storage System: Supported by High-Availability Storage System Monitor (dm_ses_enclosure)

1010DNone

HP SureStore E Disk System: Supported by High-Availability Storage System Monitor (dm_ses_enclosure)

SC10None

HP SureStore Disk System: Supported by High-Availability Storage System Monitor (dm_ses_enclosure)

2300None

HP SureStore Disk System: Supported by High-Availability Storage System Monitor (dm_ses_enclosure)

2405None

 

Fibre Channel SCSI Multiplexer Monitor (dm_fc_scsi_mux) supports A3308A HP Fibre Channel SCSI Multiplexer. The monitor requires firmware version 3840.

Table 2-5 lists the supported Fibre Channel adapters and their requirements.

Table 2-3 Fibre Channel Adapters

ProductModel/Product NumberSpecial Requirements

HP Fibre Mass Storage Channel Adapters: Supported by Fibre Channel Mass Storage Channel Adapter (dm_FCMS_adapter)

A3404A
A3591A
A3636A
A3740A

For product support information, see the IT Resource Center at:

http://itrc.hp.com

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

HP Fibre Channel Mass Storage Channel Adapter: Supported by Fibre Channel Mass Adapter Monitor (dm_TL_adapter)

A5158A
A6684A
A6685A
A6795A

For information about the driver and the STM versions required for the Fibre Channel host bus adapters, see the IT Resource Center at:

http://itrc.hp.com

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

HP Fibre Channel Mass Storage Adapters

Supported by Fibre Channel Adapter Monitor (dm_ql_adapter)

A6826A, A9782A

HP-UX 11i v1 September 2003 release of the Support Tools bundle or later

For information about the driver and the STM versions required for the Fibre Channel host bus adapters, see the IT Resource Center at:

http://itrc.hp.com

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

HP Fibre Channel Mass Storage Adapters

Supported by Fibre Channel Adapter Monitor (dm_ql_adapter)

403619-B21: 2-port 4Gbps PCIe Fibre Channel Mezzanine Adapter

AD000–60002: 2-port 2Gbps PCIe Fibre Channel Mezzanine Adapter

HP-UX 11i v3 September 2007 release or later

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

HP Fibre Channel Mass Storage Adapters

Supported by Fibre Channel Adapter Monitor (dm_ql_adapter)

AD193A and AD194A GigE cards

HP-UX 11i v1 December 2006 release or later

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

HP Fibre Channel Mass Storage Adapters

Supported by Raid Adapters Monitor (dm_raid_adapter)

A7992A

HP-UX 11i v1 September 2003 release of the Support Tools bundle or later

For information about the driver and the STM versions required for the Fibre Channel host bus adapters, see the IT Resource Center at:

http://itrc.hp.com

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

HP Fibre Channel Mass Storage Adapters

Supported by Raid Adapters Monitor (dm_raid_adapter)

AH319A: 4-port PCIe SAS SmartArray P400i RAID Mezzanine Adapter

HP-UX 11i v3 September 2007 release or later

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

HP SAS Mass Storage Adapter

Supported by SAS Mass Storage Adapter Monitor (dm_sas_adapter)

SAS_399490-001

HP-UX 11i v2 June 2006 release or later

For information about the driver and the STM versions required for the Fibre Channel host bus adapters, see the IT Resource Center at:

http://itrc.hp.com

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

HP SAS Mass Storage Adapter

Supported by SAS Mass Storage Adapter Monitor (dm_sas_adapter)

405132-B21 and 405160-B21 - PCIe SAS

399490-001 and 435234-001 - PCI-x SAS

HP-UX 11i v2 June 2007 release or later

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

Fibre Channel Emulex Adapters

Emulex PCI-e Fibre Channel Adapter monitor (dm_fclp_adapter)

AD299A 1p 4Gb FC (PCIe)

AD355A 2p 4Gb FC (PCIe)

HP-UX 11i v2 June 2007 release or later

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

Fibre Channel Emulex Adapters

Emulex PCI-e Fibre Channel Adapter monitor (dm_fclp_adapter)

AD221A: HP PCIe 1p 1000BT Adapter

AD222A: HP PCIe 2p 1000BT Adapter

AD393A: HP PCIe 2p 1000SX Adapter

HP-UX 11i v3 September 2007 release or later

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

 

The Fibre Channel Arbitrated Loop Hub Monitor (dm_fc_hub) supports the following models of the Fibre Channel Arbitrated Loop (FC-AL) hubs.

  • A3724A

  • A4839A

The FC-AL Hub monitor requires the following device firmware revisions:

  • Device Agent Firmware revision 2.14 or later

  • Hub Controller Firmware revision 3.06 or later

    Firmware and installation instructions are available at:

    http://www.hp.com/go/softwaredepot

Before using the hub monitor, edit the monitor configuration file (/var/stm/config/tools/monitor/dm_fc_hub.cfg) to specify the hubs to be monitored.

The Fibre Channel Switch Monitor (dm_fc_sw) supports the following models of Fibre Channel Switch:

  • A5223A

  • A5224A

  • A5625A

  • A7347A

Before using the switch monitor, edit the monitor configuration file (/var/stm/config/tools/monitor/dm_fc_sw.cfg) to specify the switches to be monitored.

The PA-RISC Memory Monitor (dm_memory) supports all system memory on PA-RISC-based systems.

The Itanium Memory Monitor (memory_ia64) supports all system memory on Itanium-based systems.

Table 2-9 lists the system requirements.

Table 2-4 System

ProductModel/Product NumberSpecial Requirements

System chassis logs: Supported by Chassis Code Monitor (dm_chassis). The monitor reads all the chassis logs in the /var/stm/logs/os/ccbootlog file.

Superdome S-ClassThis requirement is applicable to HP-UX 11i v1 only. The chassis code logging daemon (cclogd) must be up and running.

Core hardware (hardware within the System Processor Unit cabinet), for example, resources associated with intake temperature. On some systems, other hardware resources, such as power supplies, are monitored: Supported by Core Hardware Monitor (dm_core_hw)

NANone

Corrected Machine Checks (CMCs) experienced by Itanium-based systems: Supported by CMC Monitor (cmc_em)

NANone

Corrected Platform Error (CPE) Monitor for all Itanium-based systems: Supported by Itanium Core Hardware Monitor (cpe_em)

NAHP-UX 11i v2 or later.

Core hardware on PA-RISC and Itanium-based systems, for example, resources associated with temperature or power supply: Supported by Itanium Core Hardware Monitor (ia64_corehw)

NANone

Low-Priority Machine Checks (LPMCs) on PA8500-based (PSCX-W) systems: Supported by LPMC Monitor (lpmc_em)

NANone

Intelligent Platform Management Interface (IPMI) Forward Progress Log (FPL) entries on the system: Supported by IPMI Forward Progress Log Monitor (fpl_em)

NAAll Itanium-based systems running HP-UX 11i v2 or later; All PA-RISC-based systems running March 2003 release of HP-UX 11i v2 or later. The ia64_corehw monitor must be running.

System status (whether the monitored systems are up and running and whether they have the Online Diagnostics software installed): Supported by System Status Monitor (sysstat_em)

NA

None

PCI Express Interface: Supported by Itanium Core Hardware Monitor (cpe_em)

rx7640

rx8640

SD16B

SD32B

SD64B

HP-UX 11i v2 December 2007 release or later

 

The SCSI123 Monitor (scsi123_em) supports SCSI1, SCSI2, and SCSI3 interface cards on all HP-UX systems.

Table 2-11 lists the requirements of other supported hardware devices.

Table 2-5 Other Supported Devices

ProductModel/Product NumberSpecial Requirements

iSCSI Subsystem HP-UX software solution for iSCSI protocol: Supported by iSCSI Subsystem Monitor (dm_iscsi_adapter)

NA

HP-UX 11i v2

For information about the driver and the STM versions required for the Fibre Channel host bus adapters, see the IT Resource Center at:

http://itrc.hp.com

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

NOTE: Starting with the HP-UX 11i v3 March 2008 release, the dm_iscsi_adapter monitor is introduced on HP 9000 and HP Integrity systems.

All storage arrays: Supported by Remote Monitor (RemoteMonitor)

  • HP A6188A Storage Array

  • HP A6189A Storage Array

  • HP A6218A Storage Array

  • HP A6189B Storage Array

None

HP UPS (Uninterruptible Power Systems): Supported by UPS Monitor (dm_ups)

HP Power Trust

  • A2941A (600VA)

  • A2994A (1300VA)

  • A2996B (1.3kVA)

  • A2997B (1.8kVA)

  • A2998B (3.0kVA)

  • A3589B (5.5kVA)

HP Power Trust II-LR

  • A1353A (2.0kVA and 120V)

  • A1354A (2.0kVA and 240V)

  • A1356A (3.0kVA and 240V)

Explorer UPS

HP Power Trust II-MR

  • A6583A (4.0kW and 240V)

  • A6584A (6.5kW and 240V)

  • A6585A (8.0kW and 240V)

The HP-UX monitoring daemon, ups_mond; this daemon is delivered on all Series 800 systems but not on S700 systems.

DS2500 Storage Enclosure

Supported by DS2500 Enclosure Monitor (gazemon)

NA

HP-UX 11i v2 June 2007 release or later

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

SCSI Tape Devices

Supported by SCSI Tape Devices monitor (dm_stape)

NA

HP-UX 11i v2 June 2007 release or later

For information about the monitor, see the monitor data sheet at:

http://docs.hp.com/en/diag

 

Printable version
Privacy statement Using this site means you accept its terms Feedback to webmaster