Agentless Data Collection Failures Due to WMI Query Errors The following information was not included in the HP Insight Dynamics – VSE for ProLiant Installation and Configuration
Guide document.
If agentless data collection fails due to WMI query errors,
this may be because the WMI performance classes in Windows have been
unregistered on the managed system, either by an inadvertent action
by an administrator or a Windows problem. In this case, the error
message displayed in the Visualization tab meter popups, and in stdout when running capcollect (either
from a command prompt or from the Optimize
Capacity Advisor
Collect Capacity
Advisor Data menu) is:
An error occurred in one or more WBEM/WMI queries to host [hostname]. Some data may be unavailable/unreliable.
Verify that the correct version of WBEM/WMI is running on the host, then try restarting the CIM Server/WMI Service on the host. |
Following are corrective actions, any one of which may
correct the problem.
Ensure that the correct version of WBEM/WMI is running
on the managed system.
Restart the CIM Server/WMI Service on the managed
system, as suggested in the error message.
Reboot the managed system.
Run the commandwmiadap /f on the
managed system. This forces an update of WMI Performance Counter classes
in Windows.