(Subsystem 110) |  |
- 2
- MESSAGE
GET_TIMER/GET_TIMER_IN_TICKS failed to get a new timer entry from TABLE MANAGEMENT. - CAUSE
All timer entries have been allocated. - ACTION
Take a system dump.
- 3
- MESSAGE
A soft interrupt occurred during wait for a timeout. - CAUSE
Pause received status from extend_receive. - ACTION
Pause will retry the timer.
- 11
- MESSAGE
The status of the timer entry is NOTIFICATION IN PROGRESS (doing SEND_MSG). - CAUSE
Timer interrupt handler has already sent notification message. - ACTION
None needed.
- 12
- MESSAGE
The status of the timer entry is non-active. - CAUSE
Release of a timer which is dormant. - ACTION
None needed.
- 13
- MESSAGE
A soft interrupt occurred during pause. - CAUSE
Pause received status from extend_receive. - ACTION
Pause will retry.
- 1002
- MESSAGE
PDC read time of day call returned with an error; the option is nonexistent. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 1003
- MESSAGE
PDC read time of day call returned with an error; the time of day is invalid. - CAUSE
Clock hardware uninitialized. - ACTION
Initialize hardware clock.
- 1010
- MESSAGE
PDC read time of day call returned with an error; the parameter is invalid. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 1102
- MESSAGE
PDC set time of day call returned with an error; the option is nonexistent. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 1103
- MESSAGE
PDC set time of day call returned with an error; the time of day is invalid. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 1110
- MESSAGE
PDC set time of day call returned with an error; the parameter is invalid. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 1202
- MESSAGE
PDC timer call (read calib. and acc.) returned with an error; the option is nonexistent. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 1203
- MESSAGE
PDC timer call (read calib. and acc.) returned with an error; the time of day is invalid. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 1210
- MESSAGE
PDC timer call (read calib. and acc.) returned with an error; the parameter is invalid. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 2002
- MESSAGE
PDC READ stable storage call returned with an error; the option is nonexistent. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 2003
- MESSAGE
PDC READ stable storage call returned with an error; can not complete call without error. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 2004
- MESSAGE
PDC READ stable storage call returned with an error; the stable storage address is invalid. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 2005
- MESSAGE
PDC READ stable storage call returned with an error; the stable storage contents are invalid. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 2010
- MESSAGE
PDC READ stable storage call returned with an error; the parameter is invalid. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 2102
- MESSAGE
PDC WRITE stable storage call returned with an error; the option is nonexistent. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 2103
- MESSAGE
PDC WRITE stable storage call returned with an error; cannot complete call without error. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 2104
- MESSAGE
PDC WRITE stable storage call returned with an error; the stable storage address is invalid. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 2105
- MESSAGE
PDC WRITE stable storage call returned with an error; the stable storage contents are invalid. - CAUSE
Same as message content. - ACTION
Take a system dump.
- 2110
- MESSAGE
PDC WRITE stable storage call returned with an error; the parameter is invalid. - CAUSE
Same as message content. - ACTION
Take a system dump.
|