1.4 Required Components for 1:1 Bandwidth with 3 Enclosures per Cabinet
The following tables indicate the required number of components for 1:1 bandwidth with 3 server blade enclosures per cabinet, depending on the total number of server blade enclosures and type of of Voltaire interconnect at full bandwidth. Back
TOC
Table 1-4: 1-12 Enclosure Configurations Using Voltaire 9024 Interconnects: Full Bandwidth
Server Blade Enclosures Control and Utility Nodes Optional 9024 Leaf Chassis to Support Control and Utility Nodes 9024 Spine Chassis Total 9024 Switch Chassis Maximum Number of 4x Link Cables                                
1 - 3 0-24 2 2 2 48                                
4 - 6 0-24 2 4 4 96                                
7 - 9 0-24 2 8 8 192                                
10 - 12 0-24 2 8 8 192                                
                               
Table 1-5: 1-6 Enclosure Configurations Using Voltaire 2004 Interconnects: Full Bandwidth                                
Server Blade Enclosures Control and Utility Nodes Number of Managed 9096 Chassis Total Number of Power Supplies Number of Fabric Boards Number of 24 Port 4X Switch Cards Maximum Number of 4x Link Cables 9024 Leaf Chassis (24*4x)                                
1 - 3 0-24 1 3 4 2 48 0                                
4 - 6 0-24 1 4 4 4 96 0                                
Table 1-6: 1-18 Enclosure Configurations Using Voltaire 2012 Interconnects: Full Bandwidth
Server Blade Enclosures Control and Utility Nodes Number of Managed 9288 Chassis Total Number of Power Supplies Number of Fabric Boards Number of 24 port 4X Switch Cards Maximum Number of 4x Link Cables 9024 Leaf Chassis (24*4x)
1 - 3  0-24 1 3 4 2 48 0
4 - 6 0-24 1 4 4 4 96 0
7 - 9 0-24 1 4 4 6 144 0
10 - 12 0-24 1 4 4 8 192 0
13 - 15 0-24 1 5 4 10 240 0
16 - 18 0-24 1 5 4 12 288 0
 
Table 1-7: 19-36 Enclosure Configurations Using Voltaire 2012 Interconnects: Full Bandwidth  
Server Blade Enclosures Control and Utility Nodes Number of Managed 9288 Chassis Total Number of Power Supplies Number of Fabric Boards Number of 24 port 4X Switch Cards Max Number of 4x Link Cables Optional 9024 Leaf Chassis to Support Control and Utility Nodes)  
19 - 21 0-24 2 6 8 14 336 2  
22 - 25 0-24 2 8 8 16 384 2  
26 - 28 0-24 2 8 8 18 432 2  
29 - 31 0-24 2 8 8 20 480 2  
32 - 34 0-24 2 10 8 22 528 2  
35 - 38 0-24 2 10 8 24 576 2